Low Dust Configuration
In this arrangement, the catalyst is situated downstream of a hot-side electrostatic precipitator, which is directly downstream of the boiler. Therefore, the flue gases entering the SCR reactor contain very low amounts of dust but are rich in SO2. The flue gas temperatures are usually sufficiently high without further heating.